{"identifier":"CVE-2026-2401","cve":{"id":"CVE-2026-2401","description":"CWE-532 Insertion of Sensitive Information into Log File vulnerability exists that could cause  confidential information to be exposed when a Web Admin user executes a malicious file provided by an attacker.","published":"2026-04-14T16:16:38.623000+00:00","modified":"2026-10-26T21:10:00.170000+00:00","status":"Analyzed","score":2.4,"severity":"LOW","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","cvss_version":"4.0","affected":[{"criteria":"cpe:2.3:a:schneider-electric:powerchute_serial_shutdown:*:*:*:*:*:*:*:*","versionStartIncluding":"","versionStartExcluding":"","versionEndIncluding":"","versionEndExcluding":"1.5"}],"weaknesses":["CWE-532"],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-104-01.pdf","source":"cybersecurity@se.com","tags":["Vendor Advisory"]}],"kev":null,"kev_checked":true,"metrics":{"cvssMetricV40":[{"source":"cybersecurity@se.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":2.4,"baseSeverity":"LOW","attackVector":"LOCAL","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"LOW","userInteraction":"PASSIVE","vulnConfidentialityImpact":"LOW","vulnIntegrityImpact":"NONE","vulnAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:N","baseScore":5.0,"baseSeverity":"MEDIUM","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":1.3,"impactScore":3.6}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-04-14T16:23:13.716274Z","id":"CVE-2026-2401","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:powerchute_serial_shutdown:*:*:*:*:*:*:*:*","versionEndExcluding":"1.5","matchCriteriaId":"503C9931-4346-4D3C-B6FF-02E663020A9D"}]}]}],"source":"nvd","retrieved_at":"2026-10-28T10:18:58.614352+00:00","exploited":false,"kev_stale":false,"products":["schneider-electric / powerchute serial shutdown"],"priority":{"label":"Assess exposure and vendor guidance","reasons":["No higher-priority signal is available in the current stored evidence."]},"epss":{"probability":0.00103,"percentile":0.00961,"date":"2026-10-27","stale":false},"version_assessment":null},"news":[],"campaigns":[],"domains":[{"domain":"download.schneider-electric.com","source_url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-104-01.pdf","investigate_url":"https://investigate.aeglixmind.com/#download.schneider-electric.com"}],"arsenal_url":"https://arsenal.aeglixmind.com/?cve=CVE-2026-2401","catalog_url":"https://cves.aeglixmind.com/cve/CVE-2026-2401","research_url":"https://investigate.aeglixmind.com/research/cve/CVE-2026-2401","coverage":{"news_candidates_checked":0,"campaign_candidates_checked":0,"bounded":false,"notice":"Exact CVE mentions in stored public excerpts and reviewed campaign content only. A mention is not proof of exploitation, attribution or tool suitability. Missing matches do not establish absence."}}