{"identifier":"CVE-2026-50719","cve":{"id":"CVE-2026-50719","description":"The Ingenic T41, and probably also T32, T40, and A1 SoC boot ROMs parse and execute an attacker-controlled init table from the SPL header before checking the secure boot state and before invoking signature verification. The init table parser supports full-address 32-bit write operations, allowing modification of SRAM-resident secure boot state prior to the verification decision. An attacker with physical write access to boot media can inject an init-table entry that disables the secure boot check, causing the ROM to accept unsigned or modified first-stage boot code. This has been hardware-validated on a secureboot-enabled T41 device; ROM analysis confirms closely related behavior on T32, T40, and A1.","published":"2026-08-19T14:17:31.977000+00:00","modified":"2026-11-09T20:10:00.200000+00:00","status":"Deferred","score":6.8,"severity":"MEDIUM","vector":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","cvss_version":"3.1","affected":[],"weaknesses":["CWE-284","CWE-347","CWE-474"],"references":[{"url":"https://opensensor.io/security/ingenic-t32-t40-t41-a1-init-table-bypass","source":"cve@mitre.org"}],"kev":null,"kev_checked":true,"metrics":{"cvssMetricV31":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":6.8,"baseSeverity":"MEDIUM","attackVector":"PHYSICAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":0.9,"impactScore":5.9}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-08-24T20:01:10.334363Z","id":"CVE-2026-50719","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[],"source":"nvd","retrieved_at":"2026-11-09T23:29:48.604622+00:00","exploited":false,"kev_stale":false,"products":[],"priority":{"label":"Assess exposure and vendor guidance","reasons":["No higher-priority signal is available in the current stored evidence."]},"epss":{"probability":0.00147,"percentile":0.03967,"date":"2026-11-18","stale":false},"version_assessment":null},"news":[],"campaigns":[],"domains":[{"domain":"opensensor.io","source_url":"https://opensensor.io/security/ingenic-t32-t40-t41-a1-init-table-bypass","investigate_url":"https://investigate.aeglixmind.com/#opensensor.io"}],"arsenal_url":"https://arsenal.aeglixmind.com/?cve=CVE-2026-50719","catalog_url":"https://cves.aeglixmind.com/cve/CVE-2026-50719","research_url":"https://investigate.aeglixmind.com/research/cve/CVE-2026-50719","coverage":{"news_candidates_checked":0,"campaign_candidates_checked":0,"bounded":false,"notice":"Exact CVE mentions in stored public excerpts and reviewed campaign content only. A mention is not proof of exploitation, attribution or tool suitability. Missing matches do not establish absence."}}